0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TEN 30-4821

TEN 30-4821

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 2 输出 5V -5V 3A,3A 36V - 75V 输入

  • 数据手册
  • 价格&库存
TEN 30-4821 数据手册
DC/DC Converter TEN 30 Series, 30 Watt • • • • 2" x 1" x 0.4" metal package • • • • Over-temperature protection Wide 2:1 input range Very high efficiency up to 91% Operating temperature range -40°C to +80°C I/O isolation 1600 VDC Adjustable output voltage Remote On/Off UL 62368-1 IEC 62368-1 The TEN 30 series is the latest generation of high performance DC/DC converter modules setting a new standard concerning power density. This product with 30W comes in an encapsulated, shielded metal package with a footprint of only 2.0” x 1.0”. All models have wide 2:1 input voltage range and precisely regulated, isolated output voltages. Advanced circuit topology provides high efficiency up to 91% which allows an industrial operating temperature range of –40°C to +80°C (with derating). Further features include remote On/Off, adjustable output, under-voltage lockout and over-temperature protection. Typical applications for these converters are mobile equipment, instrumentation, distributed power architectures in communication and industrial electronics and everywhere where space on the PCB is critical. Models Order Code Input Voltage Range TEN 30-1210 TEN 30-1211 TEN 30-1212 TEN 30-1213 TEN 30-1221 TEN 30-1222 TEN 30-1223 TEN 30-2410 TEN 30-2411 TEN 30-2412 TEN 30-2413 TEN 30-2421 TEN 30-2422 TEN 30-2423 TEN 30-4810 TEN 30-4811 TEN 30-4812 TEN 30-4813 TEN 30-4821 TEN 30-4822 TEN 30-4823 www.tracopower.com 9 - 18 VDC (12 VDC nom.) 18 - 36 VDC (24 VDC nom.) 36 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5.1 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC +5 VDC +12 VDC +15 VDC 8'000 mA 6'000 mA 2'500 mA 2'000 mA 3'000 mA 1'250 mA 1'000 mA 8'000 mA 6'000 mA 2'500 mA 2'000 mA 3'000 mA 1'250 mA 1'000 mA 8'000 mA 6'000 mA 2'500 mA 2'000 mA 3'000 mA 1'250 mA 1'000 mA September 20, 2023 Vnom Efficiency Imax –5 VDC –12 VDC –15 VDC 3'000 mA 1'250 mA 1'000 mA –5 VDC –12 VDC –15 VDC 3'000 mA 1'250 mA 1'000 mA –5 VDC –12 VDC –15 VDC 3'000 mA 1'250 mA 1'000 mA typ. 85 % 87 % 89 % 89 % 87 % 87 % 87 % 87 % 90 % 91 % 91 % 90 % 89 % 90 % 87 % 89 % 91 % 91 % 90 % 88 % 89 % Page 1 / 5 TEN 30 Series, 30 Watt Options TEN-HS1 - Optional Heat Sink with Height = 0.22 inch: www.tracopower.com/products/ten-hs1.pdf - Optional model with 1.5 VDC / 8'500 mA Output and 9 - 18 VDC Input - Optional model with 2.5 VDC / 8'000 mA Output and 9 - 18 VDC Input on demand - Optional model with 1.5 VDC / 8'500 mA Output and 18 - 36 VDC Input (backorder with MOQ non stocking item) - Optional model with 2.5 VDC / 8'000 mA Output and 18 - 36 VDC Input - Optional model with 1.5 VDC / 8'500 mA Output and 36 - 75 VDC Input - Optional model with 2.5 VDC / 8'000 mA Output and 36 - 75 VDC Input Input Specifications Input Current - At no load - At full load Surge Voltage Under Voltage Lockout Reflected Ripple Current Recommended Input Fuse Input Filter 12 Vin models: 70 mA typ. (1.5 Vout model) 100 mA typ. (2.5 Vout model) 105 mA typ. (3.3 Vout model) 130 mA typ. (5.1 Vout model) 90 mA typ. (12 Vout model) 80 mA typ. (15 Vout model) 120 mA typ. (5 / -5 Vout model) 50 mA typ. (12 / -12 Vout model) 40 mA typ. (15 / -15 Vout model) 24 Vin models: 50 mA typ. (1.5 Vout model) 50 mA typ. (2.5 Vout model) 50 mA typ. (3.3 Vout model) 75 mA typ. (5.1 Vout model) 40 mA typ. (12 Vout model) 35 mA typ. (15 Vout model) 70 mA typ. (5 / -5 Vout model) 30 mA typ. (12 / -12 Vout model) 30 mA typ. (15 / -15 Vout model) 48 Vin models: 45 mA typ. (1.5 Vout model) 45 mA typ. (2.5 Vout model) 30 mA typ. (3.3 Vout model) 45 mA typ. (5.1 Vout model) 45 mA typ. (12 Vout model) 50 mA typ. (15 Vout model) 35 mA typ. (5 / -5 Vout model) 30 mA typ. (12 / -12 Vout model) 20 mA typ. (15 / -15 Vout model) 12 Vin models: 3'000 mA typ. 24 Vin models: 1'500 mA typ. 48 Vin models: 750 mA typ. 12 Vin models: 25 VDC max. (100 ms max.) 24 Vin models: 50 VDC max. (100 ms max.) 48 Vin models: 100 VDC max. (100 ms max.) 12 Vin models: 7 VDC min. / 8 VDC typ. / 8.8 VDC max. 24 Vin models: 15 VDC min. / 16 VDC typ. / 17.5 VDC max. 48 Vin models: 31.5 VDC min. / 33 VDC typ. / 34.5 VDC max. 20 mA typ. 12 Vin models: 6'300 mA (slow blow) 24 Vin models: 3'150 mA (slow blow) 48 Vin models: 1'600 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 2 / 5 TEN 30 Series, 30 Watt Output Specifications Output Voltage Adjustment See application note: Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) - Cross Regulation (25% / 100% asym. load) - single output - dual output Capacitive Load - single output - dual output single output models: dual output models: single output models: dual output models: dual output models: 1.5 Vout models: 2.5 Vout models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 5 / -5 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 1.5 Vout models: 2.5 Vout models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 5 / -5 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Overload Protection Output Current Limitation Overvoltage Protection Transient Response - Peak Variation - Response Time ±10% (single output models only) (By external trim resistor) www.tracopower.com/overview/ten30 Output power must not exceed rated power! ±1% max. 0.2% max. 0.2% max. 0.5% max. 1% max. (Output 1) 1% max. (Output 2) 5% max. 100 mVp-p typ. (w/ 1 µF, 50 V MLCC) 100 mVp-p typ. (w/ 1 µF, 50 V MLCC) 100 mVp-p typ. (w/ 1 µF, 50 V MLCC) 100 mVp-p typ. (w/ 1 µF, 50 V MLCC) 150 mVp-p typ. (w/ 1 µF, 50 V MLCC) 150 mVp-p typ. (w/ 1 µF, 50 V MLCC) 100 / 100 mVp-p typ. (w/ 1 µF, 50 V MLCC) 150 / 150 mVp-p typ. (w/ 1 µF, 50 V MLCC) 150 / 150 mVp-p typ. (w/ 1 µF, 50 V MLCC) 20'000 µF max. 20'000 µF max. 20'000 µF max. 14'400 µF max. 3'000 µF max. 2'000 µF max. 3'000 / 3'000 µF max. 2'000 / 2'000 µF max. 1'300 / 1'300 µF max. Not required ±0.02 %/K max. 30 ms typ. Continuous, Automatic recovery Indefinite Mode 150% typ. of Iout max. 125% typ. of Vout nom. (depending on model) 2 VDC typ. (1.5 Vout models) 3.3 VDC typ. (2.5 Vout models) 3.9 VDC typ. (3.3 Vout models) 6.2 VDC typ. (±5 & 5.1 Vout models) 15 VDC typ. (±12 Vout models) 18 VDC typ. (±15 Vout models) 450 mV max. (25% Load Step) 250 µs typ. (25% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment - Certification Documents EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/ten30 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 3 / 5 TEN 30 Series, 30 Watt Pollution Degree Over Voltage Category PD 2 OVC I EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions EMS Immunity External filter proposal: Air: Contact: - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 55032 class A (with external filter) EN 55032 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/ten30 EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A 12 Vin & 24 Vin models (KY 330 µF / 50 V) 48 Vin models (KY 220 µF / 100V) EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating - Operating Temperature - Case Temperature - Storage Temperature - High Temperature Over Temperature Protection Switch Off - Protection Mode - Measurement Point Cooling System Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process Environment - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF - Vibration - Mechanical Shock - Thermal Shock Housing Material Base Material Potting Material 95% max. (non condensing) –40°C to +80°C +105°C max. –55°C to +125°C Depending on model See application note: www.tracopower.com/overview/ten30 115°C typ. (Automatic recovery at 105°C typ.) Case Natural convection (20 LFM) On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 3 mA typ. -0.5 to 0.5 mA 5'000 m max. 387 - 473 kHz (PWM) 430 kHz typ. (PWM) Functional Insulation 1'600 VDC 1'600 VDC 1'600 VDC 1'000 MΩ min. 1'500 pF max. 1'450'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf MIL-STD-810F 7.7 g, 3 axis, random waveform, 60 min MIL-STD-810F 40 g, 3 axis, terminal peak sawtooth, 11 ms MIL-STD-810F -55°C to +125°C, 72 cycles, 30 min each Copper, Nickel plated Non-conductive FR4 (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 4 / 5 TEN 30 Series, 30 Watt Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Copper Nickel (2 - 3 µm) Tin (3 - 5 µm), matte Metal Case PCB Mount THD (Through-Hole Device) 2" x 1" Lead-Free Wave Soldering 265°C / 10 s max. 30.5 g Weight Thermal Impedance - Case to Ambient Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number 12 K/W typ. 10 K/W typ. (with Heat Sink) www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 8337096d-4657-4963-9344-853fadd7ae91 Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/ten30 Outline Dimensions 15.24 (0.600) Pinout 5.08 Pin (0.100) 2.54 (0.100) 50.8 (2.00) 45.72 (1.800) 3 2 1 Bottom view 6 5 20.32 Single Dual 1 +Vin (Vcc) 2 –Vin (GND) 3 Remote On/Off 4 +Vout 5 –Vout Common 6 Trim –Vout 4 10.16 5.6 10.2 (0.400) (0.800) (0.22) (0.40) 25.4 (1.00) Dimensions in mm (inch) Pin diameter: 1.0 ±0.1 (0.04 ±0.004) Tolerances: x.x ±0.5 (x.xx ±0.02) x.xx ±0.25 (x.xxx ±0.01) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 20, 2023 Page 5 / 5
TEN 30-4821 价格&库存

很抱歉,暂时无法提供与“TEN 30-4821”相匹配的价格&库存,您可以联系我们找货

免费人工找货